hotline:
010-53033961
中文
Home
About
News
Product
Service
Case
Contact
hotline:
010-59393252
×
Company News
News
Technical Popularization
How does IMPRESIND gas radiant heating system guarantee operation safety?
time:2024-01-23
hits:623次
source:正弘奥能
<p> At present, the tall space heating. What are the safety requirements of gas infrared radiant heating systems? How should we protect it? According to the relevant national requirements for fire safety regulations, the overall design idea of fire safety in the building gas use site is to install combustible gas detectors in the gas use site, transmit the detection alarm signal to the fire alarm controller host, and control the cut-off solenoid valve and explosion-proof exhaust system on the transmission pipe, and cut off the electricity consumption of non-fire control facilities. </p> <p> <br /> </p> <p style="text-align:center;"> <img src="http://www.leadwaypower.com/Uploads/image/20240123/20240123094028_36853.png" alt="" /> </p> <br /> The IMPRESIND gas radiant heating system promoted and sold by Beijing Leadway Power Co., Ltd. is taken as an example. The generator adopts double fan, micro-positive pressure and negative pressure system design, and double wind pressure differential switch configuration. When the system starts, the micro positive pressure fan starts, after the micro difference switch is closed, the negative pressure fan starts, after the negative pressure switch is closed, the burner ignits. The micro positive pressure fan can ensure the stability of the flame without flame spillover, and the negative pressure fan can well elongate the flame in the radiation tube to ensure the combustion efficiency. The dual fan configuration ensures flame safety to a large extent.<br /> <br /> <p> In addition, the generator internal combustion valve system uses a multi-functional combined gas valve, which is tightly combined with a filter, regulator and pressure monitor. Meets DIN EN 161 Class A Class 2 requirements. Slow opening and fast closing, stable combustion, prevent deflagration. There is a flame ion monitoring port (fire window) in the generator, which can check whether the ignition needle is normal, whether the flame is normal, and the whole device is completely closed, which can effectively ensure the safety of debugging or maintenance personnel. </p> <p> <br /> </p> <p style="text-align:center;"> <img src="http://www.leadwaypower.com/Uploads/image/20240123/20240123094014_48713.png" alt="" /> </p> <br /> <span>IMPRESIND</span> Gas radiant heating system burners burn natural gas and the resulting hot fluid flows through the radiant tube driven by a smoke exhaust fan (vacuum pump). The radiation tube is made of real double-sided aluminized black gray alloy steel, which makes the surface heat radiation more uniform and the heat radiation efficiency higher. After the heat exchange of the hot fluid inside the radiation tube is completed, part of the product will be recycled (about 40%) through the premix chamber, and the other part will be discharged outside by the exhaust fan. Secondary heating to achieve energy saving, environmental protection, high efficiency, reduce operating costs.<br /> <br /> According to Article 3.1.1 of the Code for Fire Protection of Building Design GBJ16-87 (2001 edition), "Various production using gas, liquid and solid as fuel or burning gas and liquid for other purposes", the fire risk category belongs to Class D. Therefore, the fire risk level of gas radiation heating system used in tall space buildings is relatively low. In the design of single-storey tall space plant, there is little difference between Class D and Class E buildings. Therefore, the use of gas radiation heating will not increase the risk and design difficulty of the building. However, it should be noted that the gas radiation heating system is prohibited to be installed in the basement, where there are flammable and explosive gases, dust and other media.<br />
prev:The application advantages of ECOPAN hot water radiant panel in large-space heating
Returns a list of
next:Heating effect of gas radiant heating system in large space